The DOI matches its Crossref record.
Space Radiation Absorbed Dose Distribution in a Human Phantom
Abstract
The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
MARE is the first experiment in general to map the dose deposition within anthropomorphic phantoms beyond LEO.
“Among these studies, MARE is the first experiment to measure the effect of wearable shielding on the deposition of radiation dose within a human phantom in space, as well as the first experiment in general to map the dose deposition within anthropomorphic phantoms beyond LEO.”
From First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I (2026) · cites this paper as [18]
MARE is the first experiment to measure the effect of wearable shielding on the deposition of radiation dose within a human phantom in space.
“Among these studies, MARE is the first experiment to measure the effect of wearable shielding on the deposition of radiation dose within a human phantom in space, as well as the first experiment in general to map the dose deposition within anthropomorphic phantoms beyond LEO.”
From First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I (2026) · cites this paper as [18]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- 10.1016/1359-0189(92)90084-9 · DOI · Paper page
- H. Yasuda, G. D. Badhwar, T. Komiyama, and K. Fujitaka .Effective dose equivalent on the ninth Shuttle-Mir mission (STS-91)., Radiat. Res, 154 :705 –713 .2000 . · DOI · Paper page
- 10.1016/1350-4487(95)00007-2 · DOI
- 10.2307/3578832 · DOI
- 10.1016/0273-1177(95)00507-B · DOI
- 10.1016/S1350-4487(00)00166-9 · DOI
- N. W. Peddie, International Geomagnetic Reference Field (IGRF): The third generation., J. Geomag. Geoelectric, 34 :309 .1982 . · DOI
- 10.1016/S1350-4487(99)00274-7 · DOI
- G. D. Badhwar, and F. A. Cucinotta .A comparison of depth dependence of dose and linear energy transfer spectra in aluminum and polyethylene., Radiat. Res, 153 :1 –8 .2000 . · DOI · Paper page
- G. D. Badhwar, H. Huff, and R. Wilkins .Alterations in dose and lineal energy spectra under different shieldings in the Los Alamos high-energy neutron field., Radiat. Res, 154 :697 –704 .2000 . · DOI
- 10.1016/S1350-4487(98)00085-7 · DOI
- A. Kunz, E. Arend, E. Deitz, S. Gerdung, R. E. Grillmaier, T. Lim, and P. Pihet .The Hamburg area monitor HANDI: Characteristics and optimization of the operational instrument., Radiat. Prot. Dosim, 44 :213 –218 .1992 . · DOI
- 10.1016/S1350-4487(00)00159-1 · DOI
- R. Beaujean, J. Kopp, and G. Reitz .Active dosimetry on recent space flights., Radiat. Prot. Dosim, 85 :223 –226 .1999 . · DOI
- 10.1016/S1350-4487(00)00149-9 · DOI
- 10.1016/S0168-9002(01)00285-6 · DOI
- 10.1109/23.736487 · DOI
- 10.1016/1359-0189(92)90082-7 · DOI
- 10.2307/3577902 · DOI
Cited by
Sorted by citations
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
ICRP Publication 123: Assessment of Radiation Exposure of Astronauts in Space
Dietze, G., Bartlett, D. T., Cool, D. A., Cucinotta, F. A., Jia, X., McAulay, I. R., Pelliccioni, M., Petrov, V., Reitz, G., & Sato, T. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2013.05.004 · Cited by 239
Physical and biological organ dosimetry analysis for international space station astronauts
Cucinotta, F. A., Kim, M.-H. Y., Willingham, V., & George, K. A. (2008) · Radiation Research · doi:10.1667/rr1330.1 · Cited by 196
Reitz, G., Berger, T., Bilski, P., Facius, R., Hajek, M., Petrov, V., Puchalska, M., Zhou, D., Bossler, J., Akatov, Y., et al. (2009) · Radiation Research · doi:10.1667/rr1559.1 · Cited by 128
Durante, M. (2002) · La Rivista del Nuovo Cimento · doi:10.1007/bf03548911 · Cited by 38
Description of Transport Codes for Space Radiation Shielding
Kim, M.-H. Y., Wilson, J. W., & Cucinotta, F. A. (2012) · Health Physics · doi:10.1097/hp.0b013e318266732f · Cited by 8
Houri, J. M., Berger, T., Gaza, R., Hussein, H., Schwarz, S., Waterman, G., Matthiä, D., Marsalek, K., Przybyla, B., Aeckerlein, J., et al. (2026) · Science Advances · doi:10.1126/sciadv.adz1892 · Cited by 2
Metadata
- Authors
- Badhwar, G. D., Atwell, W., Badavi, F. F., Yang, T. C., & Cleghorn, T. F.
- Affiliations
- National Aeronautics and Space Administration (US)
- Boeing (United States) (US)
- Christopher Newport University (US)
- Johnson Space Center (US)
- Venue
- Radiation Research
- Publisher
- Radiation Research Society
- Published
- 2002-01
- Volume
- 157
- Issue
- 1
- Pages
- 76-91
- ISSN
- 0033-7587 (ISSN-L)
- 1938-5404
- OpenAlex
- W2146653418
- Cited by
- 86
- References
- 0
- Citations by year
- 2026: 3 · 2025: 3 · 2023: 4 · 2022: 5 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 10
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiation Research (publishedVersion)
- PubMed (publishedVersion)
- BioOne Complete (BioOne) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Keywords
- space radiation, absorbed dose distribution, human phantom, STS-91, International Space Station, organ dose, skin dose, trapped protons, galactic cosmic rays, radiation transport models, tissue equivalent proportional counter, dose equivalent, radiation shielding, thermal neutrons, astronaut radiation risk
- MeSH terms
- Abdomen, Bone Marrow, Brain, Cosmic Radiation, Equipment Design, Humans, Lithium, Male, Models, Theoretical, Neutrons, Organ Specificity, Protons, Radiation Dosage, Radiation Protection, Skin, Space Flight, Spinal Cord, Testis, Thermoluminescent Dosimetry, Thorax, Thyroid Gland, Viscera, Astronauts, Spacecraft, Risk Assessment, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review